An analysis of the magnetic pull force which arises between the poles of an electromagnet

You're viewing an older version of this page (#3618). View the current version.

View versions (1)

Consider an electromagnet of area A and magnetic flux density B, and also imagine a displacement of \delta x as highlighted in Figure 1.

Figure 1
Figure 1

We know that the energy stored in a magnetic field of no magnetic saturation is given by:

E_{stored} = V \frac{B^2}{2 \mu_0 \mu_r}
(3)

where V is the volume, \mu_0 the magnetic permeability of free space, and \mu_r the relative magnetic permeability (for a more detailed discussion on the energy stored in a magnetic field see Stored Energy ).

Thus, the change in energy stored following the displacement \delta x will be:

\delta E_{stored} = \delta V \frac{B^2}{2 \mu_0 \mu_r}
(4)

where \delta V (=A \delta x) is the change in volume. This leads to:

\delta E_{stored} = A \delta x \frac{B^2}{2 \mu_0 \mu_r} (=W)
(5)

where W refers to the work done. However, we also know that work can also be defined as:

W = F \delta x
(6)

where F is the force (Newtons).

Taking into account equations (#3) and (#4), we get that:

\calc{A*(B^2/(8*π*10^(-7)*mu_r))} "Instant calculator eq(6)"

F \delta x = A \delta x \frac{B^2}{2 \mu_0 \mu_r}
(7)

from which the magnetic pull force becomes:

F = A \frac{B^2}{2 \mu_0 \mu_r}
(8)
Example 1 [metric]
Problem

Consider the electromagnet diagramed in Figure E1, characterised by the lengths l_1 = 20 \; cm, l_2 = 15 \; cm, and l_g = 0.001 \; cm, and the area A = 10 \; cm^2. Given that a current of i = 1  A passes through a coil with N = 200 turns and relative magnetic permeability of \mu_r = 3000, find the total magnetic pull force.

Figure E1
Figure E1
Workings

We know that the total magnetic reluctance of a magnetic circuit of length l, cross-sectional area A, and relative magnetic permeability \mu_r, with an air gap of length l_g, is given by:

\mathcal{R} = \frac{l}{\mu_0 \mu_r A} + \frac{l_g}{\mu_0 A}
(9)

As, in our case, l=l_1+l_2=20+15 \; cm (=(20+15)\cdot 10^{-2} \; m), A=10\; cm^2 (=10\cdot 10^{-4} \; m^2), \mu_r = 3000, and l_g=0.001 \; cm (=0.001 \cdot 10^{-2} \; m), we obtain the total magnetic reluctance:

\mathcal{R} = \frac{(20+15)\cdot 10^{-2}}{4\pi \cdot 10^{-7}\cdot 3000 \cdot 10 \cdot 10^{-4}} + 2\cdot \frac{0.001 \cdot 10^{-2}}{4\pi \cdot 10^{-7} \cdot 10 \cdot 10^{-4}}
(10)

which gives:

\mathcal{R} = 10.88 \cdot 10^4 \; \frac{At}{Wb}
(11)

The total magnetic flux is given by:

\Phi = \frac{\mathcal{F}}{\mathcal{R}}
(12)

where \mathcal{F} is the magnetomotive force:

\mathcal{F} = Ni
(13)

As, in our case, N=200, i=1\; A, and \mathcal{R}=10.88 \cdot 10^4 \; At/Wb (from equation #3), we obtain from (#4) and (#5) that the total magnetic flux is:

\Phi = \frac{200\cdot 1}{10.88\cdot 10^4} = 18.38 \cdot 10^{-4} \; Wb
(14)

Taking into account that the magnetic flux density B is given by:

B = \frac{\Phi}{A}
(15)

and also considering (#6) and that A=10\; cm^2 (=10\cdot 10^{-4} \; m^2), we obtain the magnetic flux density in the air gap:

B_g = \frac{18.38 \cdot 10^{-4}}{10\cdot 10^{-4}} = 1.838 \; \frac{Wb}{m^2}
(16)

As the magnetic pull force is given by:

F = A \frac{B^2}{2 \mu_0 \mu_r}
(17)

and also considering (#8), and that A=10\; cm^2 (=10\cdot 10^{-4} \; m^2), and the relative magnetic permeability of air is \mu_r = 1, the magnetic pull per pole becomes:

A \frac{B_g^2}{2 \mu_0 \mu_r} = 10 \cdot 10^{-4} \cdot \frac{1.838^2}{2 \cdot 4\pi \cdot 10^{-7} \cdot 1} = 1345.6 \; N
(18)

Thus, we obtain the total magnetic pull force:

Solution
F= 2 \cdot 1345.6 = 2691 \; N
(19)